EATON-ATS2-MIB DEFINITIONS ::= BEGIN

IMPORTS
	OBJECT-TYPE, NOTIFICATION-TYPE, MODULE-IDENTITY, 
	Counter32
		FROM SNMPv2-SMI
	TEXTUAL-CONVENTION, DisplayString
		FROM SNMPv2-TC
	sts
		FROM EATON-OIDS;

ats2 MODULE-IDENTITY
	LAST-UPDATED "201407311200Z"
	ORGANIZATION 
		"Eaton Corporation"
	CONTACT-INFO 
		"www.eaton.com"
	DESCRIPTION 
		"The MIB module for Eaton ATS (Automatic Transfer Switch)."

	REVISION "201407311200Z"
	DESCRIPTION 
		"Initial release."
::= { sts 2 }


-- EatonSTS-MIB { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) eaton(534) sts(10) ats2(2) }

ats2Ident			OBJECT IDENTIFIER ::=  { ats2 1 }
ats2Measure			OBJECT IDENTIFIER ::=  { ats2 2 }
ats2Status			OBJECT IDENTIFIER ::=  { ats2 3 }
ats2Config			OBJECT IDENTIFIER ::=  { ats2 4 }
ats2Environment OBJECT IDENTIFIER ::= {ats2 5}
ats2Traps			OBJECT IDENTIFIER ::=  { ats2 10 }

-- Textual Conventions
UnixTimeStamp ::= TEXTUAL-CONVENTION
  DISPLAY-HINT      "dddddddddd"
	STATUS     current
	DESCRIPTION 
		"Unix time stamp.  Measured in seconds since January 1, 1970."
	SYNTAX  Counter32

--
-- Identification group
ats2IdentManufacturer OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..16))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The manufacturer name."
	::= { ats2Ident 1 }

ats2IdentModel	OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..32))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Device model name."
	::= { ats2Ident 2 }

ats2IdentFWVersion OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..16))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Device F/W version."
	::= { ats2Ident 3 }

ats2IdentRelease OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..16))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The released date."
	::= { ats2Ident 4 }

ats2IdentSerialNumber OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..20))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Device serial number"
	::= { ats2Ident 5 }

ats2IdentPartNumber OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..20))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Device part number"
	::= { ats2Ident 6 }

ats2IdentAgentVersion OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..20))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Communication Card F/W version"
	::= { ats2Ident 7 }

--
-- Mesurement group
ats2Input		OBJECT IDENTIFIER ::=  { ats2Measure 1 }

ats2InputDephasing OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS		"degrees"
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The dephasing in between Source 1 and Source 2."
	::= { ats2Input 1 }

ats2InputTable OBJECT-TYPE
	SYNTAX		SEQUENCE OF ATSInputEntry
	MAX-ACCESS  	not-accessible
	STATUS		current
	DESCRIPTION
		"The table of input information."
	::= { ats2Measure 2 }

ats2Output			OBJECT IDENTIFIER ::=  { ats2Measure 3 }

ats2OperationMode OBJECT-TYPE
	SYNTAX		INTEGER {
		initialization(1),
		diagnosis(2),
		off(3),
		source1(4),
		source2(5),
		safe(6),
		fault(7)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The operation mode."
	::= { ats2Measure 4 }

--
-- Mesurement / Input group
ats2InputEntry OBJECT-TYPE
	SYNTAX		ATSInputEntry
	MAX-ACCESS  	not-accessible
	STATUS		current
	DESCRIPTION
		"The input information of each source input:
		<node>.1   source1
		<node>.2   source2"
	INDEX { ats2InputIndex }
	::= { ats2InputTable 1 }

ATSInputEntry ::= SEQUENCE {
	ats2InputIndex		INTEGER,
	ats2InputVoltage		INTEGER,
	ats2InputFrequency	INTEGER
}

ats2InputIndex OBJECT-TYPE
	SYNTAX		INTEGER {
		source1(1),
		source2(2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Index to input."
	::= { ats2InputEntry 1 }

ats2InputVoltage OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "0.1 V"
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The input voltage in front of relay. Units are 0.1 V."
	::= { ats2InputEntry 2 }

ats2InputFrequency OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "0.1 Hz"
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The input frequency.  Units are 0.1 Hz."
	::= { ats2InputEntry 3 }

--
-- Mesurement / Output group
ats2OutputVoltage OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS		"0.1 V"
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The output voltage. Units are 0.1 V."
	::= { ats2Output 1 }

ats2OutputCurrent OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS		"0.1 A"
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The output current. Units are 0.1 A."
	::= { ats2Output 2 }


--
-- Status group
ats2InputStatus		OBJECT IDENTIFIER ::=  { ats2Status 1 }

ats2InputStatusDephasing OBJECT-TYPE
	SYNTAX		INTEGER {
		normal (1),
		outOfRange (2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The dephasing status in between Source 1 and Source 2."
	::= { ats2InputStatus 1 }

ats2InputStatusTable OBJECT-TYPE
	SYNTAX		SEQUENCE OF ATSInputStatusEntry
	MAX-ACCESS		not-accessible
	STATUS		current
	DESCRIPTION
		"The table of input status."
	::= { ats2Status 2 }

ats2OutputStatus			OBJECT IDENTIFIER ::=  { ats2Status 3 }

--
-- Status / Input Flow group
ats2InputStatusEntry OBJECT-TYPE
	SYNTAX		ATSInputStatusEntry
	MAX-ACCESS  	not-accessible
	STATUS		current
	DESCRIPTION
		"The input flow status:
		<node>.1   source1
		<node>.2   source2"
	INDEX { ats2InputStatusIndex }
	::= { ats2InputStatusTable 1 }

ATSInputStatusEntry ::= SEQUENCE {
	ats2InputStatusIndex			INTEGER,
	ats2InputStatusFrequency				INTEGER,
	ats2InputStatusGood	INTEGER,
	ats2InputStatusInternalFailure	INTEGER,
	ats2InputStatusVoltage	INTEGER,
	ats2InputStatusUsed			INTEGER
}

ats2InputStatusIndex OBJECT-TYPE
	SYNTAX		INTEGER {
		source1(1),
		source2(2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Index of input entry."
	::= { ats2InputStatusEntry 1 }

ats2InputStatusFrequency OBJECT-TYPE
	SYNTAX		INTEGER {
		good (1),
		outOfRange (2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The status of input frequency."
	::= { ats2InputStatusEntry 2 }

ats2InputStatusGood OBJECT-TYPE
	SYNTAX		INTEGER {
		voltageOrFreqOutofRange(1),
		voltageAndFreqNormalRange(2),
		voltageDeratedRangeAndFreqNormalRange(3),
		voltageAndFreqNormalRangeWaveformNok(4)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The summarized status of input AC flow."
	::= { ats2InputStatusEntry 3 }

ats2InputStatusInternalFailure OBJECT-TYPE
	SYNTAX		INTEGER {
		good (1),
		internalFailure (2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The internal fault status of input."
	::= { ats2InputStatusEntry 4 }

ats2InputStatusVoltage OBJECT-TYPE
	SYNTAX		INTEGER {
		normalRange(1),
		deratedRange(2),
		outofRange(3),
    missing(4)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The status of input voltage."
	::= { ats2InputStatusEntry 5 }

ats2InputStatusUsed OBJECT-TYPE
	SYNTAX		INTEGER {
		notPoweringLoad(1),
		poweringLoad(2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The status of input relay."
	::= { ats2InputStatusEntry 6 }

--
-- Status / Failure group
ats2StatusInternalFailure OBJECT-TYPE
	SYNTAX		INTEGER {
		good (1),
		internalFailure (2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Output fault."
	::= { ats2OutputStatus 1 }

ats2StatusOutput OBJECT-TYPE
	SYNTAX		INTEGER {
		outputNotPowered(1),
		outputPowered(2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Output powered status."
	::= { ats2OutputStatus 2 }

ats2StatusOverload OBJECT-TYPE
	SYNTAX		INTEGER {
		noOverload(1),
		warningOverload(2),
		criticalOverload(3)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The output overload status."
	::= { ats2OutputStatus 3 }

ats2StatusOverTemperature OBJECT-TYPE
	SYNTAX		INTEGER {
		noOverTemperature(1),
		overTemperature(2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The over temperature status."
	::= { ats2OutputStatus 4 }

ats2StatusShortCircuit OBJECT-TYPE
	SYNTAX		INTEGER {
		noShortCircuit(1),
		shortCircuit(2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Short circuit status."
	::= { ats2OutputStatus 5 }

ats2StatusCommunicationLost OBJECT-TYPE
	SYNTAX		INTEGER {
		good (1),
		communicationLost (2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Communication failure status."
	::= { ats2OutputStatus 6 }

ats2StatusConfigurationFailure OBJECT-TYPE
	SYNTAX		INTEGER {
		good (1),
		configurationFailure (2)
	}
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"Configuration failure status."
	::= { ats2OutputStatus 7 }

--
-- Configuration group
ats2ConfigTime		OBJECT IDENTIFIER ::=  { ats2Config 1 }

ats2ConfigInputVoltageRating OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "1 V"
	MAX-ACCESS    read-only
	STATUS		current
	DESCRIPTION
		"The input voltage rating. Unit is 1 V."
	::= { ats2Config 2 }

ats2ConfigInputFrequencyRating OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "Hz"
	MAX-ACCESS    read-only
	STATUS		current
	DESCRIPTION
		"The input frequency rating. Unit is 1 Hz."
	::= { ats2Config 3 }

ats2ConfigOutputVoltage OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "1 V"
	MAX-ACCESS    read-write
	STATUS		current
	DESCRIPTION
		"The output voltage config. Unit is 1 V."
	::= { ats2Config 4 }

ats2ConfigPreferred OBJECT-TYPE
	SYNTAX		INTEGER {
		source1(1),
		source2(2)
	}
	MAX-ACCESS    read-write
	STATUS		current
	DESCRIPTION
		"The preferred source."
	::= { ats2Config 5 }

ats2ConfigSensitivity OBJECT-TYPE
	SYNTAX		INTEGER {
		normal(1),
    highSensitivity (2),
    lowSensitivity (3)
	}
	MAX-ACCESS    read-write
	STATUS		current
	DESCRIPTION
		"The AC Blackout Sensitivity."
	::= { ats2Config 6 }

ats2ConfigTransferMode OBJECT-TYPE
	SYNTAX		INTEGER {
		standard(1),
		gap(2)
	}
	MAX-ACCESS    read-write
	STATUS		current
	DESCRIPTION
		"behavior configuration when transfering from one source to other source not synchronized."
	::= { ats2Config 7 }

ats2ConfigTransferTest OBJECT-TYPE
	SYNTAX		INTEGER {
    doneAndPassed (1),
    doneAndWarning (2),            
    doneAndError (3),
    aborted (4),
    inProgress (5),
    noTestInitiated (6)
	}
	MAX-ACCESS    read-only
	STATUS		current
	DESCRIPTION
		"The status of transfer test."
	::= { ats2Config 8 }

ats2ConfigBrownoutLow OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "1 V"
	MAX-ACCESS    read-only
	STATUS		current
	DESCRIPTION
		"Setting of input brownout low voltage. Unit is 1 V."
	::= { ats2Config 9 }

ats2ConfigBrownoutLowDerated OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "1 V"
	MAX-ACCESS    read-only
	STATUS		current
	DESCRIPTION
		"Setting of input brownout low derated voltage. Unit is 1 V."
	::= { ats2Config 10 }

ats2ConfigBrownoutHigh OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "1 V"
	MAX-ACCESS    read-only
	STATUS		current
	DESCRIPTION
		"Setting of input brownout high voltage. Unit is 1 V."
	::= { ats2Config 11 }

ats2ConfigHysteresisVoltage OBJECT-TYPE
	SYNTAX		INTEGER
	UNITS      "1 V"
	MAX-ACCESS    read-only
	STATUS		current
	DESCRIPTION
		"Hysteresis between loss point and comeback point. Unit is 1 V."
	::= { ats2Config 12 }

--
-- Configuration / Time group
ats2ConfigTimeRTC  OBJECT-TYPE
	SYNTAX     UnixTimeStamp
	MAX-ACCESS     read-write
	STATUS     current
	DESCRIPTION 
		"Clock value.  This could be from either a real-time clock (in which case
		 it is likely writeable) or from a time server via NTP (probably read-only).
     (since 1/1/1970 at 1:00:00)."
	::= { ats2ConfigTime 1 }

ats2ConfigTimeTextDate OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..10))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The present date in MM/DD/YYYY text format."
	::= { ats2ConfigTime 2 }

ats2ConfigTimeTextTime OBJECT-TYPE
	SYNTAX		DisplayString (SIZE(0..8))
	MAX-ACCESS		read-only
	STATUS		current
	DESCRIPTION
		"The present time in hh:mm:ss text format."
	::= { ats2ConfigTime 3 }


--
-- EMP group
--
-- The objects defined in this group are provided by the EMP.
-- They are Temperature and Humidity readings and alarming limits,
-- and the (two) contacts readings and setup information.
-- These objects are related to the separate EMP probe that can be connected to
-- the communication card.
--
-- Notices/Traps: traps related to the probe are 
--      ats2tdRemoteTempBad
--      ats2tdRemoteHumidityBad
--      ats2tdContactActiveNotice
--      ats2tdContactInactiveNotice


ats2EnvRemoteTemp OBJECT-TYPE
    SYNTAX  INTEGER (-100..200)   
    UNITS       "degrees Centigrade"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The reading of an EMP's temperature sensor."
    ::= { ats2Environment  1 }

ats2EnvRemoteHumidity OBJECT-TYPE
    SYNTAX  INTEGER (0..100)  
    UNITS       "percent"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The reading of an EMP's humidity sensor."
    ::= { ats2Environment  2 }

--
-- The Environmental Contact Sensing Table
--      Contains the table for monitoring all contacts (digital 
--      inputs, normally 2 in an EMP).
--

ats2EnvNumContacts OBJECT-TYPE
    SYNTAX  INTEGER (1..1024)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
       "The number of Contacts in the ats2ContactSenseTable.
        This object indicates the number of rows in the 
        ats2ContactSenseTable."
    ::= { ats2Environment  3 }

ats2ContactSenseTable OBJECT-TYPE
    SYNTAX  SEQUENCE OF Ats2ContactsTableEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "A list of Contact Sensing table entries.  
        The number of entries is given by the value of 
        ats2EnvNumContacts."
    ::= { ats2Environment  4 }

ats2ContactsTableEntry OBJECT-TYPE
    SYNTAX  Ats2ContactsTableEntry
    MAX-ACCESS  not-accessible
    STATUS  current
    DESCRIPTION
       "An entry containing information applicable 
        to a particular Contact input."
    INDEX   { ats2ContactIndex }
    ::= { ats2ContactSenseTable  1 }

Ats2ContactsTableEntry ::= SEQUENCE {
    ats2ContactIndex   INTEGER,
    ats2ContactType    INTEGER,
    ats2ContactState   INTEGER,
    ats2ContactDescr   DisplayString
    }

ats2ContactIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..1024)
    MAX-ACCESS  read-only           -- actually not-accessible
    STATUS  current
    DESCRIPTION
       "The Contact identifier; identical to the Contact Number.
        This object is not-accessible to MIB browsers, but had to be changed to
        read-only to satisfy SMIv2 syntax checkers if it is included in traps."
    ::= { ats2ContactsTableEntry  1 }

ats2ContactType OBJECT-TYPE
    SYNTAX  INTEGER {
        normallyOpen(1),            -- or Input Normally High
        normallyClosed(2),          -- or Input Normally Low
        anyChange(3),               -- No normal Open/Closed state
        notUsed(4)                  -- Contact not in service or not alarming
        }
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "The normal state for this contact.  The 'other' (not 'Normally')
        state is the Active state for generating the ats2tdContactActiveNotice
        trap.  If anyChange(3) is selected, then this trap is sent
        any time the contact changes to either Open or Closed.
        No traps are sent if the Contact is set to notUsed(4).
        In many cases, the configuration for Contacts may be done by other 
        means, so this object may be read-only."
    ::= { ats2ContactsTableEntry  2 }

ats2ContactState OBJECT-TYPE
    SYNTAX  INTEGER {
        open(1),
        closed(2),
        openWithNotice(3),
        closedWithNotice(4)
        }
    MAX-ACCESS  read-only
    STATUS  current
    DESCRIPTION
       "The current state of the Contact input;
        the value is based on the open/closed input state 
        and the setting for ats2ContactType.
        When entering the openWithNotice(3) and closedWithNotice(4) 
        states, no entries added to the ats2AlarmTable, but
        the ats2tdContactActiveNotice trap is sent."
    ::= { ats2ContactsTableEntry  3 }

ats2ContactDescr OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..63))
    MAX-ACCESS  read-write
    STATUS  current
    DESCRIPTION
       "A label identifying the Contact.  This object should be
        set by the administrator."
    ::= { ats2ContactsTableEntry  4 }

ats2EnvRemoteTempLowerLimit OBJECT-TYPE
    SYNTAX  INTEGER (-100..200) 
    UNITS       "degrees Centigrade"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The Lower Limit of the EMP temperature; if ats2EnvRemoteTemp 
        falls below this value, the ats2RemoteTempBad alarm will occur."
    ::= { ats2Environment  5 }

ats2EnvRemoteTempUpperLimit OBJECT-TYPE
    SYNTAX  INTEGER (-100..200) 
    UNITS       "degrees Centigrade"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The Upper Limit of the EMP temperature; if ats2EnvRemoteTemp 
        rises above this value, the ats2RemoteTempBad alarm will occur.
        This value should be greater than ats2EnvRemoteTempLowerLimit."
    ::= { ats2Environment  6 }

ats2EnvRemoteHumidityLowerLimit OBJECT-TYPE
    SYNTAX  INTEGER (0..100) 
    UNITS       "percent"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The Lower Limit of the EMP humidity reading; if ats2EnvRemoteHumidity
        falls below this value, the ats2RemoteHumidityBad alarm will occur."
    ::= { ats2Environment  7 }

ats2EnvRemoteHumidityUpperLimit OBJECT-TYPE
    SYNTAX  INTEGER (0..100) 
    UNITS       "percent"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
       "The Upper Limit of the EMP humidity reading; if ats2EnvRemoteHumidity 
        rises above this value, the ats2RemoteHumidityBad alarm will occur.
        This value should be greater than ats2EnvRemoteHumidityLowerLimit."
    ::= { ats2Environment  8 }


--
-- Traps / Notifications for the EMP in the PowerMIB style
-- The special EMP traps are not normally provided by Power Xpert Gateways (which use
-- the PXG-style traps instead) but could be provided by PowerMIB implementations
-- These are found in the PowerMIB:
--    ats2tdContactActiveNotice   
--    ats2tdContactInactiveNotice 
--    ats2tdRemoteTempBad         
--    ats2tdRemoteHumidityBad     




--
-- Traps group
ats2TrapCommunicationLost NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Communication with the ATS failed."
	::= { ats2Traps 1 }

ats2TrapCommunicationRecovered NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Communication with the ATS recovered."
	::= { ats2Traps 2 }

ats2TrapOutputPowered NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"The ATS powers the load."
	::= { ats2Traps 3 }

ats2TrapOutputNotPowered NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"The ATS does not powers the load."
	::= { ats2Traps 4 }

ats2TrapOverload NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"The ATS has sensed a critical overload."
	::= { ats2Traps 5 }

ats2TrapNoOverLoad NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"The critical overload disappeared."
	::= { ats2Traps 6 }

ats2TrapInternalFailure NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"The ATS has an internal failure (sum of all HW internal failure)."
	::= { ats2Traps 7 }

ats2TrapNoInternalFailure NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"The ATS internal failure disappeared."
	::= { ats2Traps 8 }

ats2TrapSource1Normal NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 1 returns to normal."
	::= { ats2Traps 9 }

ats2TrapSource1OutOfRange NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 1 out of range."
	::= { ats2Traps 10 }

ats2TrapSource2Normal NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 2 returns to normal."
	::= { ats2Traps 11 }

ats2TrapSource2OutOfRange NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 2 out of range."
	::= { ats2Traps 12 }

ats2TrapSourceDesynchronized NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 1 and Source 2 phase are desynchronized."
	::= { ats2Traps 13 }

ats2TrapSourceSynchronized NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 1 and Source 2 phase are synchronized."
	::= { ats2Traps 14 }
  
ats2TrapOutputPoweredBySource1 NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 1 powers the output."
	::= { ats2Traps 15 }
  
ats2TrapOutputPoweredBySource2 NOTIFICATION-TYPE
	STATUS     current
	DESCRIPTION
	"Source 2 powers the output."
	::= { ats2Traps 16 }

-- Added to provide additional information with the RemoteTemp and RemoteHumidity 
ats2TrapRemoteTempLow NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
       "The remote temperature, ats2EnvRemoteTemp, has fallen below 
    the set lower limit, ats2EnvRemoteTempLowerLimit." 
    --#SEVERITY MAJOR 
    ::= { ats2Traps 20 }

ats2TrapRemoteTempHigh NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
       "The remote temperature, ats2EnvRemoteTemp, has risen above 
    the set upper limit, xupsEnvRemoteTempUpperLimit." 
    --#SEVERITY MAJOR 
    ::= { ats2Traps 21 }

ats2TrapRemoteTempNormal NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
       "The remote temperature, ats2EnvRemoteTemp, is inside the interval
       defined by the lower limit and the upper limit." 
    --#SEVERITY MAJOR 
    ::= { ats2Traps 22 }

ats2TrapRemoteHumidityLow NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
       "The remote humidity, ats2EnvRemoteHumidity, has fallen below 
    the set lower limit, ats2EnvRemoteHumidityLowerLimit." 
    --#SEVERITY MAJOR 
    ::= { ats2Traps 23 }

ats2TrapRemoteHumidityHigh NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
       "The remote humidity, ats2EnvRemoteHumidity, has risen above 
    the set upper limit, ats2EnvRemoteHumidityUpperLimit." 
    --#SEVERITY MAJOR 
    ::= { ats2Traps 24 }

ats2TrapRemoteHumidityNormal NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
       "The remote humidity, ats2EnvRemoteHumidity, is inside the interval
       defined by the lower limit and the upper limit." 
    --#SEVERITY MAJOR 
    ::= { ats2Traps 25 }

ats2Contact1ActiveNotice NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
    "The Contact 1 is in its Active state.
     The following are the situations that generate this trap:
        For ats2ContactType:    and     ats2ContactState: 
            normallyOpen(1)     and     closedWithNotice(4)
            normallyClosed(2)   and     openWithNotice(3)
            anyChange(3)        and     openWithNotice(3) or closedWithNotice(4)"
    --#SEVERITY MAJOR
    ::= { ats2Traps 26 }

ats2Contact1InactiveNotice NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
    "The Contact 1 has changed to its Inactive state."
    --#SEVERITY INFORMATIONAL
    ::= { ats2Traps 27 }

ats2Contact2ActiveNotice NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
    "The Contact 2 is in its Active state.
     The following are the situations that generate this trap:
        For ats2ContactType:    and     ats2ContactState: 
            normallyOpen(1)     and     closedWithNotice(4)
            normallyClosed(2)   and     openWithNotice(3)
            anyChange(3)        and     openWithNotice(3) or closedWithNotice(4)"
    --#SEVERITY MAJOR
    ::= { ats2Traps 28 }

ats2Contact2InactiveNotice NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
    "The Contact 2 has changed to its Inactive state."
    --#SEVERITY INFORMATIONAL
    ::= { ats2Traps 29 }

ats2TestTrap NOTIFICATION-TYPE
    STATUS     current
    DESCRIPTION
    "Sent whenever the trap test feature is used by the communication card."
    --#SEVERITY INFORMATIONAL
    ::= { ats2Traps 40 }


END