-- * Firebrick CPU MIB
-- *
-- * June 2020, Cliff Hones
-- *
-- * Copyright (c) 2020 by Andrews & Arnold
-- *------------------------------------------------

FIREBRICK-CPU-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    Integer32,
    enterprises
        FROM SNMPv2-SMI
    DisplayString
        FROM SNMPv2-TC
    InetAddressType,
    InetAddress
        FROM INET-ADDRESS-MIB
    OBJECT-GROUP
        FROM SNMPv2-CONF
    firebrickNewStyle
        FROM FIREBRICK-MIB
        ;

fbCpuMib MODULE-IDENTITY
    LAST-UPDATED "202207150000Z"
    ORGANIZATION "Andrews & Arnold Limited"
    CONTACT-INFO
        "Andrews & Arnold
        Unit 1&2, Enterprise Court
        Bracknell, Berkshire, RG12 1QS
        United Kingdom

        Tel: +44 3333 400 999
        Email: support@aa.net.uk"
    DESCRIPTION "Firebrick CPU usage"
    REVISION "202207150000Z"
    DESCRIPTION "Additional validation"
    REVISION "202006170000Z"
    DESCRIPTION "Initial version of this MIB module"
    ::= { firebrickNewStyle 2 }

fbCpuUsageTable OBJECT-TYPE
    SYNTAX SEQUENCE OF FbCpuUsageEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "CPU usage for this Firebrick"
    ::= { fbCpuMib 1 }

fbCpuUsageEntry OBJECT-TYPE
    SYNTAX FbCpuUsageEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "An entry in the CPU usage table"
    INDEX { fbCpuPeriod, fbCpuCore }
    ::= { fbCpuUsageTable 1 }

FbCpuUsageEntry ::= SEQUENCE {
    fbCpuIRQ      Gauge32,
    fbCpuAll      Gauge32,
    fbCpuIRQPeak  Gauge32,
    fbCpuAllPeak  Gauge32,
    fbCpuPeriod   Integer32,
    fbCpuCore     Integer32
}

fbCpuPeriod OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "The period in minutes covered by this table entry.
         Zero indicates that an instantaneous value is required.
         Max is 30 minutes."
    ::= { fbCpuUsageEntry 5 }

fbCpuCore OBJECT-TYPE
    SYNTAX Integer32
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION
        "The CPU core number covered by this table entry.
         The numbering starts at 1, so CPU0 1, CPU1 is 2 etc."
    ::= { fbCpuUsageEntry 6 }

fbCpuIRQ OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The percentage of CPU time spent in interrupt processing for this period.
         If period is 0 the instantaneous usage in the last second is used.
         Units are 100ths of a percent, so 10000 indicates 100%."
    ::= { fbCpuUsageEntry 1 }

fbCpuAll OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The total percentage of CPU time spent non-idle for this period.
         If period is 0 the instantaneous usage in the last second is used.
         Units are 100ths of a percent, so 10000 indicates 100%."
    ::= { fbCpuUsageEntry 2 }

fbCpuIRQPeak OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The peak percentage of CPU time in interrupt processing during this period.
         If period is 0 the peak usage in the current minute is used.
         Units are 100ths of a percent, so 10000 indicates 100%."
    ::= { fbCpuUsageEntry 3 }

fbCpuAllPeak OBJECT-TYPE
    SYNTAX Gauge32
    MAX-ACCESS read-only
    STATUS current
    DESCRIPTION
        "The peak percentage of CPU time non-idle during this period.
         If period is 0 the peak usage in the current minute is used.
         Units are 100ths of a percent, so 10000 indicates 100%."
    ::= { fbCpuUsageEntry 4 }
END